Affiliated company manufacturing sites :Fukushima Rubber Co., Ltd.

Fukushima Rubber Co., Ltd.

Location 28 Domae, Miyashiro, Fukushima-shi, Fukushima 960-0116 Japan
Telephone +81-24-553-1356
Products Ordinary industrial rubber products, automotive parts,
water-impermeable sheets, rigid polyurethane products
Site area 63,432m²
Total floor space 30,037m²
Number of employees
at the end of FY2015
236 people

Environmental impact data

Item unit FY2011 FY2012 FY2013 FY2014 FY2015
CO2 emissions per unit of production t-CO2/t 1.666 1.723 1.755 1.754 1.889
Landfill waste per unit of production t/t 0 0 0.0001 0.0001 0
Water consumption t 415 407 412 407 402

Atmospheric pollutant measurement (emitted gas concentration)

Equipment SOx NOx Soot and dust
Regulatory value Measured value Regulatory value Measured value Regulatory value Measured value
No.2 boiler 10 1.031 180 95 0.30 0.009
No.4 boiler 10 0.592 180 100 0.30 0.008
No.6 boiler 10 0.992 180 120 0.30 0.007
No.7 boiler 10 0.400 180 110 0.30 0.009
No.8 boiler 10 0.390 180 110 0.30 0.009

Water pollutant measurement

Item Regulatory value Maximum Minimum Average
pH 5.8 – 8.6 7.6 7.1 7.3
BOD 25 7.3 1.6 3.5
COD 40 6.3 1.6 3.7
SS 70 6.2 1.0 3.0
n-Hex(mineral oil) 5 <0.5 <0.5 <0.5
Zinc 2 0.04 0.02 0.03
Total coliform 3,000 0 0 0

Substances subject to the PRTR law

Offic No. Substance Emission Amount transferred
Atmosphere Water Waste products etc. Sewage
42 2-Imidazolidinethione 0 0 3 0
80 Xylene 986 0 0 0
155 N-(cyclohexylthio)phthalimide 0 0 11 0
189 N,N-dicyclohexyl-2-benzothiazolesulfenamide 0 0 4 0
205 1,3-diphenylguanidine 0 0 7 0
230 N-(1,3-dimethylbutyl)-N’-phenyl-p-phenylenediamine 0 0 82 0
258 Hexamethylenetetramine 0 0 24 0
300 Toluene 43,647 0 4,147 0
349 Phenol 0 0 25 0
355 bis(2-ethylhexyl)phthalate 0 0 28 0
372 N-(tert-Butyl)-2-benzothiazolesulfenamide 0 0 54 0
Atmospheric pollutant measurements
  • For actual measured values, the highest measured values are shown.
  • For regulatory values, the strictest value from all relevant laws, ordinances and agreements is shown.
  • Regulatory value units
    NOx: ppm
    SOx: Sendai Plant use m³N/h, while all other bases use K values
    Soot and dust: g/m³N
    Dioxins: ng-TEQ/m³Nfor gas emissions
    Burnt residue: ng-TEQ/g
Water pollutant measurement
  • For regulatory values, the strictest value from all relevant laws, ordinances and agreements is shown.
  • Units are mg/L, except for pH and coliform bacteria, which is organisims/cm³
    pH: hydrogen ion concentration,
    BOD: biological oxygen demand,
    COD: chemical oxygen demand,
    SS: suspended solid concentration in water
Substances subject to the PRTR law
  • Units are given rounded to the nearest kg
  • The unit for dioxins is mg-TEQ/year with two significant digits

Domestic manufacturing sites

Affiliated company manufacturing sites

Overseas manufacturing sites

ACTION FOR CSR